Main |
Range of product |
Altivar Process ATV900 |
Device application |
Industrial application |
Product or component type |
Variable speed drive |
Product destination |
Synchronous motors |
Asynchronous motors |
Product specific application |
Process for industrial |
Variant |
Standard version |
Without braking chopper |
Network number of phases |
3 phases |
Mounting mode |
Wall mount |
Communication port protocol |
Modbus serial |
EtherNet/IP |
Modbus TCP |
[Us] rated supply voltage |
380…480 V – 15…10 % |
Continuous output current |
481 A at 2.5 kHz for normal duty |
387 A at 2.5 kHz for heavy duty |
EMC filter |
Integrated |
With EMC plate option |
IP degree of protection |
IP21 |
Degree of protection |
UL type 1 |
option module |
Slot A: communication module for Profibus DP V1 |
Slot A: communication module for PROFINET |
Slot A: communication module for DeviceNet |
Slot A: communication module for EtherCAT |
Slot A: communication module for CANopen daisy chain RJ45 |
Slot A: communication module for CANopen SUB-D 9 |
Slot A: communication module for CANopen screw terminals |
Slot A/slot B/slot C: digital and analog I/O extension module |
Slot A/slot B/slot C: output relay extension module |
Slot B: 5/12 V digital encoder interface module |
Slot B: analog encoder interface module |
Slot B: resolver encoder interface module |
communication module for Ethernet Powerlink |
Discrete input logic |
16 preset speeds |
Motor power kW |
250.0 kW for normal duty |
200.0 kW for heavy duty |
Asynchronous motor control profile |
Variable torque standard |
Constant torque standard |
Optimized torque mode |
Synchronous motor control profile |
Permanent magnet motor |
Synchronous reluctance motor |
Maximum output frequency |
599 Hz |
Switching frequency |
1…8 kHz adjustable |
2.5…8 kHz with derating factor |
Nominal switching frequency |
2.5 kHz |
Line current |
451.0 A at 380 V (normal duty) |
365.0 A at 380 V (heavy duty) |
366.0 A at 480 V (normal duty) |
301.0 A at 480 V (heavy duty) |
Apparent power |
279 kVA at 480 V (normal duty) |
229 kVA at 480 V (heavy duty) |
Maximum transient current |
577 A during 60 s (normal duty) |
581 A during 60 s (heavy duty) |
Network frequency |
50…60 Hz |
Prospective line Isc |
50 kA |
Complementary |
Discrete input number |
10 |
Discrete input type |
DI1…DI8 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm |
DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) |
STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm |
Discrete output number |
2 |
Discrete output type |
Logic output DQ+ 0…1 kHz <= 30 V DC 100 mA |
Programmable as pulse output DQ+ 0…30 kHz <= 30 V DC 20 mA |
Logic output DQ- 0…1 kHz <= 30 V DC 100 mA |
Analogue input number |
3 |
Analogue input type |
AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits |
AI1, AI2, AI3 software-configurable current: 0…20 mA/4…20 mA, impedance: 250 Ohm, resolution 12 bits |
Analogue output number |
2 |
Analogue output type |
Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits |
Software-configurable current AQ1, AQ2: 0…20 mA impedance 500 Ohm, resolution 10 bits |
Relay output number |
3 |
Relay output type |
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles |
Configurable relay logic R2: sequence relay NO electrical durability 1000000 cycles |
Configurable relay logic R3: sequence relay NO electrical durability 1000000 cycles |
Maximum switching current |
Relay output R1 on resistive load, cos phi = 1: 3 A at 250 V AC |
Relay output R1 on resistive load, cos phi = 1: 3 A at 30 V DC |
Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC |
Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
Relay output R2, R3 on resistive load, cos phi = 1: 5 A at 250 V AC |
Relay output R2, R3 on resistive load, cos phi = 1: 5 A at 30 V DC |
Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC |
Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
Minimum switching current |
Relay output R1, R2, R3: 5 mA at 24 V DC |
Physical interface |
Ethernet |
2-wire RS 485 |
Connector type |
2 RJ45 |
1 RJ45 |
Method of access |
Slave Modbus TCP |
Transmission rate |
10, 100 Mbits |
4.8 kbps |
9600 bit/s |
19200 bit/s |
Transmission frame |
RTU |
Number of addresses |
1…247 |
Data format |
8 bits, configurable odd, even or no parity |
Type of polarization |
No impedance |
4 quadrant operation possible |
FALSE |
Acceleration and deceleration ramps |
Linear adjustable separately from 0.01…9999 s |
Motor slip compensation |
Adjustable |
Can be suppressed |
Automatic whatever the load |
Not available in permanent magnet motor law |
Braking to standstill |
By DC injection |
Brake chopper integrated |
FALSE |
Maximum input current |
451.0 A |
Maximum output voltage |
480.0 V |
Relative symmetric network frequency tolerance |
5% |
Base load current at high overload |
387.0 A |
Base load current at low overload |
481.0 A |
Power dissipation in W |
Forced convection: 5773 W at 380 V, switching frequency 2.5 kHz |
Natural convection: 606 W at 380 V, switching frequency 2.5 kHz |
With safety function Safely Limited Speed (SLS) |
TRUE |
With safety function Safe brake management (SBC/SBT) |
TRUE |
With safety function Safe Operating Stop (SOS) |
FALSE |
With safety function Safe Position (SP) |
FALSE |
With safety function Safe programmable logic |
FALSE |
With safety function Safe Speed Monitor (SSM) |
FALSE |
With safety function Safe Stop 1 (SS1) |
TRUE |
With sft fct Safe Stop 2 (SS2) |
FALSE |
With safety function Safe torque off (STO) |
TRUE |
With safety function Safely Limited Position (SLP) |
FALSE |
With safety function Safe Direction (SDI) |
FALSE |
Protection type |
Thermal protection: motor |
Safe torque off: motor |
Motor phase break: motor |
Thermal protection: drive |
Safe torque off: drive |
Overheating: drive |
Overcurrent between output phases and earth: drive |
Overload of output voltage: drive |
Short-circuit protection: drive |
Motor phase break: drive |
Overvoltages on the DC bus: drive |
Line supply overvoltage: drive |
Line supply undervoltage: drive |
Line supply phase loss: drive |
Overspeed: drive |
Break on the control circuit: drive |
Quantity per set |
1 |
Width |
598 mm |
Height |
1195 mm |
Depth |
380 mm |
Net weight |
203 kg |
Electrical connection |
Control: screw terminal 0.5…1.5 mm²/AWG 20…AWG 16 |
Line side: screw terminal 4 x 185 mm²/3 x 350 kcmil |
Motor: screw terminal 4 x 185 mm²/3 x 350 kcmil |
DC bus: screw terminal 4 x 185 mm²/3 x 350 kcmil |
Transmission rate |
10/100 Mbit/s for Ethernet IP/Modbus TCP |
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
Exchange mode |
Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP |
Data format |
8 bits, configurable odd, even or no parity for Modbus serial |
Type of polarization |
No impedance for Modbus serial |
Number of addresses |
1…247 for Modbus serial |
Supply |
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection |
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection |
Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection |
Local signalling |
Local diagnostic: 3 LED (mono/dual colour) |
Presence of voltage: 1 LED (red) |
Embedded communication status: 3 LED (dual colour) |
Communication module status: 4 LED (dual colour) |
Input compatibility |
DI1…DI8: discrete input level 1 PLC conforming to IEC 61131-2 |
DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68 |
STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2 |
Discrete input logic |
Positive logic (source) (DI1…DI8), < 5 V (state 0), > 11 V (state 1) |
Negative logic (sink) (DI1…DI8), > 16 V (state 0), < 10 V (state 1) |
Positive logic (source) (DI7, DI8), < 0.6 V (state 0), > 2.5 V (state 1) |
Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1) |
Sampling duration |
2 ms +/- 0.5 ms (DI1…DI8) – discrete input |
5 ms +/- 1 ms (DI7, DI8) – pulse input |
1 ms +/- 1 ms (AI1, AI2, AI3) – analog input |
5 ms +/- 1 ms (AQ1, AQ2) – analog output |
Accuracy |
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input |
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
Linearity error |
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input |
AQ1, AQ2: +/- 0.2 % for analog output |
Refresh time |
Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
Isolation |
Between power and control terminals |
Environment |
Operating altitude |
<= 1000 m without derating |
1000…3000 m with current derating 1 % per 100 m |
Operating position |
Vertical +/- 10 degree |
Product certifications |
UL |
CSA |
TÜV |
Marking |
CE |
Standards |
UL 508C |
IEC 61800-3 |
IEC 61800-5-1 |
IEC 61000-3-12 |
IEC 60721-3 |
IEC 61508 |
IEC 13849-1 |
Maximum THDI |
<48 % full load conforming to IEC 61000-3-12 |
Assembly style |
Enclosed |
Electromagnetic compatibility |
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 |
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 |
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 |
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 |
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
Environmental class (during operation) |
Class 3C3 according to IEC 60721-3-3 |
Class 3S3 according to IEC 60721-3-3 |
Maximum acceleration under shock impact (during operation) |
150 m/s² at 11 ms |
Maximum acceleration under vibrational stress (during operation) |
10 m/s² at 13…200 Hz |
Maximum deflection under vibratory load (during operation) |
1.5 mm at 2…13 Hz |
Permitted relative humidity (during operation) |
Class 3K5 according to EN 60721-3 |
Volume of cooling air |
1260 m3/h |
Overvoltage category |
III |
Regulation loop |
Adjustable PID regulator |
Insulation resistance |
> 1 MOhm 500 V DC for 1 minute to earth |
Noise level |
76 dB conforming to 86/188/EEC |
Vibration resistance |
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 |
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
Shock resistance |
15 gn for 11 ms conforming to IEC 60068-2-27 |
Environmental characteristic |
Chemical pollution resistance class 3C2 conforming to IEC 60721-3-3 |
Dust pollution resistance class 3S2 conforming to IEC 60721-3-3 |
Relative humidity |
5…95 % without condensation conforming to IEC 60068-2-3 |
Ambient air temperature for operation |
-10…40 °C (without derating) |
40…60 °C (with derating factor) |
Noise level |
76 dB |
pollution degree |
2 |
Ambient air transport temperature |
-25…70 °C |
Ambient air temperature for storage |
-25…70 °C |